Difference between revisions of "Sekonic RT-32CTL module"

From PocketWizard Wiki
Jump to: navigation, search
(Created page with "==Product Description== The RT-32CTL module for compatible Sekonic light meters allows you to trigger ControlTL® radios receiving on ControlTL channels. This allows you to use...")
 
Line 30: Line 30:
 
Newer L-758 DigitalMaster light meters can select Standard and ControlTL Channels and zones independently.
 
Newer L-758 DigitalMaster light meters can select Standard and ControlTL Channels and zones independently.
  
The L-358, and previous versions of the L-758 meter, use a channel mapping mode to pair up Standard and ControlTL channels automatically.
+
The L-358, and previous versions of the L-758 meter, use a channel mapping mode (see table below) to pair up Standard and ControlTL channels automatically.
  
 
Learn more about PockeWizard Channels [[Channels|here.]]
 
Learn more about PockeWizard Channels [[Channels|here.]]
Line 50: Line 50:
 
**If using Zones (only available on Channels 17-32) use the four buttons on the meter labeled in blue with A,B,C, and D.
 
**If using Zones (only available on Channels 17-32) use the four buttons on the meter labeled in blue with A,B,C, and D.
 
**Once you have your Channel (and Zones if applicable) set, press the triggering button located on the right side of the meter.
 
**Once you have your Channel (and Zones if applicable) set, press the triggering button located on the right side of the meter.
 +
 +
 +
'''Sekonic Channel mapping'''
 +
 +
<table border="1">
 +
<tr>
 +
<th rowspan="2">Meter Channel</th>
 +
<th colspan="2">Standard Channel</th>
 +
<th colspan="2">ControlTL Channel</th>
 +
</tr>
 +
<tr>
 +
<th>Plus II</th>
 +
<th>Plus III/MultiMAX</th>
 +
<th>FCC</th>
 +
<th>CE</th>
 +
</tr>
 +
<tr>
 +
<td align="center">1</td>
 +
<td align="center">1</td>
 +
<td align="center">1</td>
 +
<td align="center">1 Zone ABC</td>
 +
<td align="center">1 Zone ABC</td>
 +
</tr>
 +
<tr>
 +
<td align="center">2</td>
 +
<td align="center">2</td>
 +
<td align="center">2</td>
 +
<td align="center">2 Zone ABC</td>
 +
<td align="center">2 Zone ABC</td>
 +
</tr>
 +
<tr>
 +
<td align="center">3</td>
 +
<td align="center">3</td>
 +
<td align="center">3</td>
 +
<td align="center">3 Zone ABC</td>
 +
<td align="center">3 Zone ABC</td>
 +
</tr>
 +
<tr>
 +
<td align="center">4</td>
 +
<td align="center">4</td>
 +
<td align="center">4</td>
 +
<td align="center">4 Zone ABC</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">5</td>
 +
<td align="center">-</td>
 +
<td align="center">5</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">6</td>
 +
<td align="center">-</td>
 +
<td align="center">6</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">7</td>
 +
<td align="center">-</td>
 +
<td align="center">7</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">8</td>
 +
<td align="center">-</td>
 +
<td align="center">8</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">9</td>
 +
<td align="center">-</td>
 +
<td align="center">9</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">10</td>
 +
<td align="center">-</td>
 +
<td align="center">10</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">11</td>
 +
<td align="center">-</td>
 +
<td align="center">11</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">12</td>
 +
<td align="center">-</td>
 +
<td align="center">12</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">13</td>
 +
<td align="center">-</td>
 +
<td align="center">13</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">14</td>
 +
<td align="center">-</td>
 +
<td align="center">14</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">15</td>
 +
<td align="center">-</td>
 +
<td align="center">15</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">16</td>
 +
<td align="center">-</td>
 +
<td align="center">16</td>
 +
<td align="center">-</td>
 +
<td align="center">-</td>
 +
</tr>
 +
<tr>
 +
<td align="center">17 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">17 Zone X</td>
 +
<td align="center">5 Zone X</td>
 +
<td align="center">1 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">18 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">18 Zone X</td>
 +
<td align="center">6 Zone X</td>
 +
<td align="center">2 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">19 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">19 Zone X</td>
 +
<td align="center">7 Zone X</td>
 +
<td align="center">3 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">20 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">20 Zone X</td>
 +
<td align="center">8 Zone X</td>
 +
<td align="center">1 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">21 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">21 Zone X</td>
 +
<td align="center">9 Zone X</td>
 +
<td align="center">2 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">22 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">22 Zone X</td>
 +
<td align="center">10 Zone X</td>
 +
<td align="center">3 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">23 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">23 Zone X</td>
 +
<td align="center">11 Zone X</td>
 +
<td align="center">1 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">24 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">24 Zone X</td>
 +
<td align="center">12 Zone X</td>
 +
<td align="center">2 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">25 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">25 Zone X</td>
 +
<td align="center">13 Zone X</td>
 +
<td align="center">3 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">26 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">26 Zone X</td>
 +
<td align="center">14 Zone X</td>
 +
<td align="center">1 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">27 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">27 Zone X</td>
 +
<td align="center">15 Zone X</td>
 +
<td align="center">2 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">28 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">28 Zone X</td>
 +
<td align="center">16 Zone X</td>
 +
<td align="center">3 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">29 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">29 Zone X</td>
 +
<td align="center">17 Zone X</td>
 +
<td align="center">1 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">30 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">30 Zone X</td>
 +
<td align="center">18 Zone X</td>
 +
<td align="center">2 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">31 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">31 Zone X</td>
 +
<td align="center">19 Zone X</td>
 +
<td align="center">3 Zone X</td>
 +
</tr>
 +
<tr>
 +
<td align="center">32 Zone X</td>
 +
<td align="center">-</td>
 +
<td align="center">32 Zone X</td>
 +
<td align="center">20 Zone X</td>
 +
<td align="center">1 Zone X</td>
 +
</tr>
 +
</table>

Revision as of 10:50, 15 June 2012

Product Description

The RT-32CTL module for compatible Sekonic light meters allows you to trigger ControlTL® radios receiving on ControlTL channels. This allows you to use an AC3 ZoneController on your transmitting MiniTT1 or FlexTT5 to set your remote flash power levels, and then meter those remote flashes using your compatible Sekonic light meter all wirelessly within the ControlTL system.


Compatibility

The RT-32CTL module can be used in the L-358, L-758D, L-758CINE and comes built in to the L-758DR Digitalmaster Sekonic light meters.

Compatible radios:

    • Flextt5 (Canon and Nikon)
    • Plus II
    • Plus III
    • MultiMAX
    • Power ST-4
    • Power MC-2


Channels

When using the RT-32CTL module in your compatible Sekonic light meter, It will simultaneously send trigger signals out on both your selected Standard Channel and selected ControlTL channel when pressing the meter’s triggering button.

Standard Channels are used with Plus II, Plus III and MultiMAX radios, as well as many flash packs with built-in PocketWizard radios. ControlTL Channels are used with the MiniTT1, FlexTT5 with Speedlites, FlexTT5 with the AC9 AlienBees Adapter, PowerST4, and PowerMC2.

Newer L-758 DigitalMaster light meters can select Standard and ControlTL Channels and zones independently.

The L-358, and previous versions of the L-758 meter, use a channel mapping mode (see table below) to pair up Standard and ControlTL channels automatically.

Learn more about PockeWizard Channels here.


To select Channels on the L-358:

    • Turn on the Sekonic light meter.
    • Once the Channel selection page comes on screen release the Mode button and use the scroll wheel to select your Channel.
    • If using Zones (only available on Channels 17-32) press the mode button once to select Zone “A” and then use the scroll wheel to select/deselect the Zone. Press the mode button to switch between Zones.
    • Once you have your Channel (and Zones if applicable) set hold the Mode button and move the scroll wheel one click to the right.


To select Channels on the L-758 (all models)

    • Turn on the Sekonic light meter.
    • Hold the Mode button and use the scroll wheel to select the wireless metering mode option.
    • Once the Channel selection page comes on screen release the Mode button and use the scroll wheel to select your Channel.
    • If using Zones (only available on Channels 17-32) use the four buttons on the meter labeled in blue with A,B,C, and D.
    • Once you have your Channel (and Zones if applicable) set, press the triggering button located on the right side of the meter.


Sekonic Channel mapping

Meter Channel Standard Channel ControlTL Channel
Plus II Plus III/MultiMAX FCC CE
1 1 1 1 Zone ABC 1 Zone ABC
2 2 2 2 Zone ABC 2 Zone ABC
3 3 3 3 Zone ABC 3 Zone ABC
4 4 4 4 Zone ABC -
5 - 5 - -
6 - 6 - -
7 - 7 - -
8 - 8 - -
9 - 9 - -
10 - 10 - -
11 - 11 - -
12 - 12 - -
13 - 13 - -
14 - 14 - -
15 - 15 - -
16 - 16 - -
17 Zone X - 17 Zone X 5 Zone X 1 Zone X
18 Zone X - 18 Zone X 6 Zone X 2 Zone X
19 Zone X - 19 Zone X 7 Zone X 3 Zone X
20 Zone X - 20 Zone X 8 Zone X 1 Zone X
21 Zone X - 21 Zone X 9 Zone X 2 Zone X
22 Zone X - 22 Zone X 10 Zone X 3 Zone X
23 Zone X - 23 Zone X 11 Zone X 1 Zone X
24 Zone X - 24 Zone X 12 Zone X 2 Zone X
25 Zone X - 25 Zone X 13 Zone X 3 Zone X
26 Zone X - 26 Zone X 14 Zone X 1 Zone X
27 Zone X - 27 Zone X 15 Zone X 2 Zone X
28 Zone X - 28 Zone X 16 Zone X 3 Zone X
29 Zone X - 29 Zone X 17 Zone X 1 Zone X
30 Zone X - 30 Zone X 18 Zone X 2 Zone X
31 Zone X - 31 Zone X 19 Zone X 3 Zone X
32 Zone X - 32 Zone X 20 Zone X 1 Zone X